MDR-100 is a slim line DIN rail Class I switching power supply.

Designed with a fully isolated plastic case to prevent user contact and the risk of shock.

Featuring up to 88% efficiency this series can be cooled using only free air convection up to 60°C which significantly increases the reliability and lifetime of the power supply.

Other standard features include its low no-load power consumption, to save energy, short circuit, overload, and over voltage protections, and DC OK relay contact with LED indicator for monitoring the PSU status.

Quick Deliver after putting an order, within 3-7 works days for common models

All products go through standardized testing procedures during production.

We make transformers and power inductors with pure coppers all by ourselves,

Global wide input volatge range 100V to 264V AC

This product is small and easy to install, which is space and cost-efficient.

Fixed switching frequency at 70KHz

The product can be cooled by convection of natural air.

Model MDR-100-12 MDR-100-15 MDR-100-24 MDR-100-48
Output DC Voltage 12V 15V 24V 48V
Rated Current 7.5A 6.7A 4A 2A
Current Range 0 ~ 7.5A 0 ~6.7A 0 -4A 0-2A
Rated Power 100W 100W 100W 100W
Ripple & Noise (max.) 80mVp-p 120mVp-p 150mVp-p 200mVp-p
Volage ADJ Range 12 -13.2V 15-16.5V 24 – 26.4V 48 ~ 56V
Voltage Tolerance ±2.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±1.0% ±1.0% ±1.0% ±1.0%
Load Regulation ±1.5% ±1.0% ±1.0% ±1.0%
Setup, Rise Time Note.5 500ms, 30ms/230VAC
500ms, 30ms/115VAC
at full load
Hold Up Time (Typ.) 50ms/230VAC
20ms/115VAC
at full load
Input Voltage Range 85~264VAC
120~370VDC
Frequency Range 47 ~ 63Hz
Efficiency (Typ.) 78% 86% 88% 87%
AC Current(Typ.) 1.8A/115VAC
1A/230VAC
Inrush Current (Typ.) Cold start:
30A/115VAC,
60A/230VAC
Leakage Current <1mA/240VAC
Protection Overload 105% – 150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Overvoltage 6.25-7.25V 15.6 – 18V 31.2-36V 57.6 – 64.8V
Protection type: Shut down o/p voltage, re-power on to recover
Function DC Signal Relay contact rating (max.): 30V/1A resistive
Environment Working Humidity 20% ~ 90%RH non-condensing
Storage Temp, Humidity -40°C ~ +85°C, 10% ~ 95%RH
Temp Coefficient ±0.03%/°C (0 – 50°C)
Vibration Component: 10 – 500Hz, 2G 10min./1 cycle, the period for 60min. each along X, Y, and Z axes; Mounting: Compliance to IEC60068-2-6
Safety & EMC Safety Standards UL508, UL60950-1, TUV EN60950-1 approved
Withstand Voltage l/P-0/P: 3KVAC
l/P-FG: 2KVAC
0/P-FG: 0.5KVAC
Isolation Resistance l/P-O/P, l/P-FG, 0/P-FG:>100M Ohms/500VDC/25°C/70% RH
EMC Emission Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
EMC Immunity Compliance to EN6100(M-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
Others MTBF 299.2K hrs min. MIL-HDBK-217F (25°C)
Dimension 50*90*100mm (W*H*D)
Packing 0.42Kg; 30pcs/20Kg/0.82CUFT
Note 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation, and load regulation.
4. The power supply is considered a component that will be installed into the final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.
5. The length of set-up time is measured at the first cold start. Turning ON/OFF the power supply may lead to an increase in the set-up time.