SP-100 is a range of enclosed power supply units featuring universal AC input and built-in power factor correction (PFC).
The SP series ranges from 75 ~ 240W, it has a wide range of protection functions against over/under voltage, over current, overload, overhead, and over temperature, as well as short circuits.
Either cooling by free air convection (SP-75 / SP-100 / SP-150) or cooling via a built-in DC fan (SP-200 / SP-240).
Series options: SP-75, SP-100, SP-150, SP-200, SP-240 SP-320 SP-500 PSP-600.
All products have passed CE and ROHS certification with guaranteed quality, this 100w power supply included.
We can tailor dimensions and functional drive modules to customer requirements.
And we make transformers and power inductors with pure coppers all by ourselves,
We choose components for the best compatibility and logical configuration
WEHO Stocks each month: common models 150000 sets, quick delivery;
The product is highly stable, the workmanship is steady, the output voltage is consistent, and there is no drift.
The power switch has surpassed the 100% full load burn-in test.
The product warranty is valid for 24 months.
Model | SP-100-5 | SP-100-12 | SP-100-24 | SP-100-48 | |
Output | DC Voltage | 5V | 12V | 24V | 48V |
Current Range | 0 ~ 20A | 0 ~ 8.5A | 0~4.2A | 0 ~ 2.1A | |
Rated Current | 20A | 8.5A | 4.2A | 2.1A | |
Rated Power | 100W | 100W | 100W | 100W | |
Ripple & Noise (max.) Note.2 | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
Voltage Adj. Range | 4.75 ~ 5.5V | 11.4 ~ 13.2V | 23.75 ~ 24.25V | 47.5 ~ 48.5V | |
Voltage Tolerance NOTE.3 | 2.00% | 2.00% | 2.00% | 2.00% | |
Line Regulation | 0.50% | ||||
Load Regulation | 1.00% | 1.00% | 1.00% | 0.50% | |
Setup, Rise Time Note.5 | 600ms, 30ms at full load | ||||
Hold Up Time (Typ.) | 20ms at full load | ||||
Input | Voltage Range | 85 ~ 264VAC 120 ~ 370VDC | |||
Frequency Range | 47 ~ 63Hz | ||||
Power Factor (Typ.) | PF>0.93/230VAC 0.98/115VAC at full load | ||||
Efficiency (Typ.) | 84% 76% | 80% | 82% | ||
AC Current (Typ.) | 1.7A/115VAC 0.8A/230VAC | ||||
Inrush Current (Typ.) | COLD START 30A/230VAC | ||||
Leakage Current | |||||
Protection | Over Load | 105 ~ 150% rated output power | |||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | |||||
Over Voltage | 5.5 ~ 6.75V | 13.2 ~ 16.2V | 23.75 ~ 24.25V | 47.5 ~ 48.5V | |
Protection type: Shut down o/p voltage, re-power on to recover | |||||
Function | Remote-control(Option) | CN3:4 ~ 10VDC POWER OFF, | |||
Environment | Working Temp. | -10 ~ +60oC (Refer to output load derating curve) | |||
Working Humidity | 20 ~ 90% RH non-condensing | ||||
Storage Temp.,
Humidity |
-20 ~ +85oC , 10 ~ 95% RH | ||||
Temp. Coefficient | 0.05%/oC (0 ~ 50oC ) | ||||
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, the period for 60min. each along the X, Y, and Z axes | ||||
Safety &EMC | Safety Standards | UL60950-1, TUV EN60950-1 approved | |||
(Note 4) | Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
EMI Conduction & Radiation | Design refers to EN55022 (CISPR22) Class B | ||||
Harmonic Current | Compliance with EN61000-3-2,-3 | ||||
EMS | Design refer to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, light industry level, criteria A | ||||
Immunity | |||||
Others | MTBF | 211.3K hrs min. MIL-HDBK-217F | |||
Dimension | 179*99*45mm (L*W*H) | ||||
Packing | 0.66Kg; 20pcs/14.3Kg/1.17CUFT |
Need Help With Finding The Right Technical Solution?
We have professional machines of General Test, wave soldering ,loading test machine , PCB ,plug-in machine ,high-low temperature machine , potting machine